Article

Suitability of a Low-Cost Wearable Sensor to Assess Turning in Healthy Adults

Details

Citation

Mason R, Byerley J, Baker A, Powell D, Pearson LT, Barry G, Godfrey A, Mancini M, Stuart S & Morris R (2022) Suitability of a Low-Cost Wearable Sensor to Assess Turning in Healthy Adults. Sensors, 22 (23), Art. No.: 9322. https://doi.org/10.3390/s22239322

Abstract
Background: Turning is a complex measure of gait that accounts for over 50% of daily steps. Traditionally, turning has been measured in a research grade laboratory setting, however, there is demand for a low-cost and portable solution to measure turning using wearable technology. This study aimed to determine the suitability of a low-cost inertial sensor-based device (AX6, Axivity) to assess turning, by simultaneously capturing and comparing to a turn algorithm output from a previously validated reference inertial sensor-based device (Opal), in healthy young adults. Methodology: Thirty participants (aged 23.9 ± 4.89 years) completed the following turning protocol wearing the AX6 and reference device: a turn course, a two-minute walk (including 180° turns) and turning in place, alternating 360° turn right and left. Both devices were attached at the lumbar spine, one Opal via a belt, and the AX6 via double sided tape attached directly to the skin. Turning measures included number of turns, average turn duration, angle, velocity, and jerk. Results: Agreement between the outcomes from the AX6 and reference device was good to excellent for all turn characteristics (all ICCs > 0.850) during the turning 360° task. There was good agreement for all turn characteristics (all ICCs > 0.800) during the two-minute walk task, except for moderate agreement for turn angle (ICC 0.683). Agreement for turn outcomes was moderate to good during the turns course (ICCs range; 0.580 to 0.870). Conclusions: A low-cost wearable sensor, AX6, can be a suitable and fit-for-purpose device when used with validated algorithms for assessment of turning outcomes, particularly during continuous turning tasks. Future work needs to determine the suitability and validity of turning in aging and clinical cohorts within low-resource settings.

Keywords
inertial sensors; turning; validation; wearables

Journal
Sensors: Volume 22, Issue 23

StatusPublished
FundersNorthumbria University, Northumbria University, Northumbria University and Private Physiotherapy Educational Foundation
Publication date31/12/2022
Publication date online30/11/2022
Date accepted by journal24/11/2022
URLhttp://hdl.handle.net/1893/36614
PublisherMDPI AG
eISSN1424-8220